Overview
By default, all calibrations are valid when they’re reported. However, calibrations can stop being valid, for example when a power cycle moves a component out of calibration. On-device applications can mark a component’s latest calibration invalid using the endpoint in the Device API. Once a calibration is invalidated, it cannot be marked valid again. Instead, simply report a new calibration for that component, which is valid by default, and the dashboard shows the latest calibration for that component as valid again.Prerequisites
To follow this guide, you must have a device installed with a Miru Agent v0.13.0 or later, and call Device API v0.3.0 at/v0.3. With the Python Device SDK, use v0.11.0 or later.
Invalidate a calibration
Calibrations are invalidated via the endpoint in the Device API. Only a component’s latest calibration can be invalidated. When a calibration is invalidated, the agent marks it invalid on the device and immediately returns a200 response, regardless of whether the device is online or offline. Once a device is online, the agent uploads the invalidation to Miru, which sets the calibration’s invalidated at.
Required parameters
To invalidate a calibration, the following parameters are required:The slug of the component whose latest calibration to invalidate.Example:
kuka-armWhy the calibration is no longer valid. Free text, at most 512 characters, and not blank.Example:
power cycleOptional parameters
In some cases, you may want to invalidate a specific calibration instead of whatever the latest resolves to be. To do so, send thereport_id of the calibration to invalidate.
The report ID of the calibration to invalidate, as read from the endpoint. If it isn’t the component’s latest calibration, the agent invalidates nothing.Example:
0b6f3c2e-6a51-4e0f-9a43-2f1d7c9e8b10Response
The agent responds with200 OK and the invalidated calibration: